Electrical Connections
THIS HOB MUST BE EARTHED.
Any electrical work required to install this hob should
be carried out by a qualified electrician or competent
person, in accordance with the current regulations.
Electrical Requirements
Any permanent electrical installation must comply with
the latest I.E.E. Regulations and local Electricity Board
regulations. For your own safety this should be undertaken
by a qualified electrician, e.g. your local Electricity Board,
or a contractor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC).
Electrical Connections
This hob is designed to be connected to a 230 V 50 Hz AC
electrical supply.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating plate.
The rating plate is located on the bottom of the hob. A copy
is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cable.
This has to be provided with a proper plug, able to support
the load marked on the identification plate. To connect the
plug to the cable, follow the recommendation given in
diagram aside. The plug has to be fitted in a proper socket.
In the event of having to change the fuse, a 3amp ASTA
approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with
the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
Connect the green and yellow (earth) wire to the
terminal in the plug which is marked with the
letter 'E' or the earth symbol or coloured green
and yellow.
Connect the blue (neutral) wire to the terminal in
the plug which is marked with the letter 'N' or
coloured black.
Connect the brown (live) wire to the terminal in
the plug which is marked with the letter 'L' or
coloured red.
Permanent Connection
In the case of a permanent connection, it is necessary
that you install a double pole switch between the hob
and the electricity supply (mains), with a minimum gap
of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the
current electric regulations.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cable does not
come into contact with surfaces with
temperatures higher than 50 deg. C.
Min. size Cable/flexMin. size Cable/flex
Min. size Cable/flexMin. size Cable/flex
Min. size Cable/flex
Cable / flex typeCable / flex type
Cable / flex typeCable / flex type
Cable / flex type
FuseFuse
FuseFuse
Fuse
0.75 mm
2
H05 V2V2-F (T90) 3 A
Supply cable replacement
The cable used to connect the hob to the electrical supply
must comply to the specifications given below.
NeutralNeutral
NeutralNeutral
Neutral
Earth (yellow/green)Earth (yellow/green)
Earth (yellow/green)Earth (yellow/green)
Earth (yellow/green)
The manufacturer declines any liability should these
safety measures not be observed.
Upon completion there must be no cut, or stray strands
of wire present and the cable clamp must be secure
over the outer sheath.
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard. Ensure that
the cut off plug is disposed of safely.